The Basics

What is Bupivacaine?

Blocks nerve impulses in your body as a local anesthetic. Given as an epidural injection into the spinal column to produce numbness during labor, surgery, or certain medical procedures.

Brand names for Bupivacaine

Sensorcaine

How Bupivacaine is classified

Anesthetics – Local

Bupivacaine During Pregnancy

Bupivacaine pregnancy category

Category CNote that the FDA has deprecated the use of pregnancy categories, so for some medications, this information isn’t available. We still think it’s useful to list historical info, however, given what a common proxy this has been in the past.

What we know about taking Bupivacaine while pregnant

There are no adequate and well-controlled studies in pregnant women. Sensorcaine should be used during pregnancy only if the potential benefit justifies the potential risk to the fetus. Bupivacaine hydrochloride produced developmental toxicity when administered subcutaneously to pregnant rats and rabbits at clinically relevant doses. This does not exclude the use of Sensorcaine at term for obstetrical anesthesia or analgesia (see Labor and Delivery). Bupivacaine hydrochloride was administered subcutaneously to rats at doses of 4.4, 13.3, & 40 mg/kg and to rabbits at doses of 1.3, 5.8, & 22.2 mg/kg during the period of organogenesis (implantation to closure of the hard palate). The high doses are comparable to the daily maximum recommended human dose (MRHD) of 400 mg/day on a mg/m body surface area (BSA) basis. No embryo-fetal effects were observed in rats at the high dose which caused increased maternal lethality. An increase in embryo-fetal deaths was observed in rabbits at the high dose in the absence of maternal toxicity with the fetal No Observed Adverse Effect Level representing approximately 1/5th the MRHD on a BSA basis. In a rat pre- and post-natal development study (dosing from implantation through weaning) conducted at subcutaneous doses of 4.4, 13.3, & 40 mg/kg mg/kg/day, decreased pup survival was observed at the high dose. The high dose is comparable to the daily MRHD of 400 mg/day on a BSA basis.

Taking Bupivacaine While Breastfeeding

What are recommendations for lactation if you're taking Bupivacaine?

Because of the low levels of bupivacaine in breastmilk, and it is not orally absorbed, amounts received by the infant are small and it has not caused any adverse effects in breastfed infants. Bupivacaine during labor and delivery with other anesthetics and analgesics has been reported by some to interfere with breastfeeding. However, this assessment is controversial and complex because of the many different combinations of drugs, dosages and patient populations studied as well as the variety of techniques used and deficient design of many of the studies. In contrast, epidural bupivacaine begun after clamping of the umbilical cord appears to enhance breastfeeding success because of improved pain control. Overall it appears that with good breastfeeding support epidural bupivacaine with or without fentanyl or one of its derivatives has little or no adverse effect on breastfeeding success.[1][2][3][4][5] Labor pain medication may delay the onset of lactation.

Maternal / infant drug levels

Because of the low levels of bupivacaine in breastmilk, and it is not orally absorbed, amounts received by the infant are small and it has not caused any adverse effects in breastfed infants. Bupivacaine during labor and delivery with other anesthetics and analgesics has been reported by some to interfere with breastfeeding. However, this assessment is controversial and complex because of the many different combinations of drugs, dosages and patient populations studied as well as the variety of techniques used and deficient design of many of the studies. In contrast, epidural bupivacaine begun after clamping of the umbilical cord appears to enhance breastfeeding success because of improved pain control. Overall it appears that with good breastfeeding support epidural bupivacaine with or without fentanyl or one of its derivatives has little or no adverse effect on breastfeeding success.[1][2][3][4][5] Labor pain medication may delay the onset of lactation.

Possible effects of Bupivacaine on milk supply

Thirty women who delivered by cesarean section received either spinal anesthesia (not defined) alone (n = 15) or spinal anesthesia plus bupivacaine (n = 15) by extradural infusion after clamping the umbilical cord. A bupivacaine bolus of 12.5 mg was followed by a continuous infusion of 17.5 mg/hour for 3 days postpartum. Patients who received bupivacaine had better pain relief as indicated by lower pain scores and a lower consumption of supplemental diclofenac for pain. Bupivacaine-treated patients also produced more milk per day than the untreated women, a difference that was statistically significant from day 3 to the end of the study on day 11 postpartum. The authors concluded that improved pain relief improved breastfeeding performance.[10]

Twenty women who delivered by cesarean section received either bupivacaine alone or bupivacaine plus buprenorphine by extradural infusion after clamping the umbilical cord. A bupivacaine bolus of 12.5 mg was followed by a continuous infusion of 17.5 mg/hour for 3 days. The buprenorphine was given as a bolus of 200 mcg followed by 8.4 mcg/hour for 3 days. Patients started breastfeeding as soon as they were able to sit up. Both the amount of milk fed and infant weight increased in both groups over the first 10 days postpartum; however, the increases were greater in those who received bupivacaine alone.[8][11]

A prospective cohort study compared women who received no analgesia (n = 63) to women who received continuous epidural analgesia with fentanyl and either bupivacaine 0.05 to 0.1% (n = 39) or ropivacaine (n = 13) during labor and delivery. The total dosage of bupivacaine was 31 to 62 mg and the average total infusion time from start to delivery was 219 minutes. The study found no differences between the groups in breastfeeding effectiveness or infant neurobehavioral status at 8 to 12 hours postpartum or the number exclusively or partially breastfeeding at 4 weeks postpartum.[12]

A randomized, prospective study measured infant breastfeeding behavior following epidural or intravenous fentanyl during delivery in 100 multiparous mothers undergoing cesarean section and delivering fullterm, healthy infants. The epidural group received epidural bupivacaine 100 mg initially, followed by a continuous infusion of 25 mg/hour. The intravenous fentanyl group received a spinal injection of 15 to 20 mg of bupivacaine. A slight difference was seen in breastfeeding behavior between the groups, with the infants in the intravenous fentanyl group performing slightly worse than those in the epidural group. However, all mothers were able to breastfeed their infants at 24 hours. None had severe breastfeeding problems; 10 women in the epidural group reported mild or moderate problems and 7 women in the intravenous group reported breastfeeding problems. Twenty mothers in the epidural group and 14 in the intravenous group used supplemental bottle feeding, with the difference not statistically significant.[13]

A randomized, but nonblinded, study in women undergoing cesarean section compared epidural anesthesia with bupivacaine to general anesthesia with intravenous thiopental 4 mg/kg and succinylcholine 1.5 mg/kg for induction followed by nitrous oxide and isoflurane. The time to the first breastfeed was significantly shorter (107 vs 228 minutes) with the epidural anesthesia than with general anesthesia. This difference was probably caused by the anesthesia’s effects on the infant, because the Apgar and neurologic and adaptive scores were significantly lower in the general anesthesia group of infants.[14]

A randomized, multicenter trial compared the initiation rate and duration of breastfeeding in women who received high-dose epidural bupivacaine alone, or one of two low-dose combinations of bupivacaine plus fentanyl. A nonepidural matched control group was also compared. No differences in breastfeeding initiation rates or duration were found among the epidural and nonmedicated, nonepidural groups.[15]

A nonrandomized study in low-risk mother-infant pairs found that there was no difference overall in the amount of sucking by newborns, whether their mothers received bupivacaine plus fentanyl, or fentanyl alone by epidural infusion in various dosages, or received no analgesia for childbirth. In a subanalysis by sex and number of sucks, female infants were affected by high-dose bupivacaine and high-dose fentanyl, but male infant were not.[16] However, the imbalance of many factors between the study groups makes this study difficult to interpret.

In a prospective cohort study, 87 multiparous women who received epidural bupivacaine and fentanyl for pain control during labor and vaginal delivery. A loading dose of 0.125% bupivacaine with fentanyl 50-100 mcg. Epidural analgesia is maintained using 0.0625% bupivacaine and fentanyl 0.2 mcg/mL. The median dose of fentanyl received by the women was 151 mcg (range 30 to 570 mcg). The women completed questionnaires at 1 and 6 weeks postpartum regarding breastfeeding. Most women had prior experience with breastfeeding, support at home and ample time off from work. All women were breastfeeding at 1 week postpartum and 95.4% of women were breastfeeding at 6 weeks postpartum.[17]

A national survey of women and their infants from late pregnancy through 12 months postpartum compared the time of lactogenesis II in mothers who did and did not receive pain medication during labor. Categories of medication were spinal or epidural only, spinal or epidural plus another medication, and other pain medication only. Women who received medications from any of the categories had about twice the risk of having delayed lactogenesis II (>72 hours) compared to women who received no labor pain medication.[18]

A randomized study compared the effects of cesarean section using general anesthesia, spinal anesthesia, or epidural anesthesia, to normal vaginal delivery on serum prolactin and oxytocin as well as time to initiation of lactation. Spinal anesthesia used bupivacaine 10 to 11 mg of hypertonic 5% bupivacaine solution and epidural anesthesia used 10 mL (50 mg) of 0.5% bupivacaine. After delivery, patients in all groups received an infusion of oxytocin 30 international units in 1 L of saline, and 0.2 mg of methylergonovine if they were not hypertensive. Patients in the general anesthesia group (n = 21) had higher post-procedure prolactin levels and a longer mean time to lactation initiation (25 hours) than in the other groups (10.8 to 11.8 hours). Postpartum oxytocin levels in the nonmedicated vaginal delivery group were higher than in the general and spinal anesthesia groups and serum oxytocin in the epidural group were higher than those in the spinal group.[19]

A retrospective study in a Spanish public hospital compared the infants of mothers who received an epidural during labor that contained fentanyl and either bupivacaine or ropivacaine. Infants of mothers who received an epidural had a lower frequency of early breastfeeding.[20]

A randomized, double-blind study compared three epidural maintenance solutions for labor analgesia in women receiving epidural analgesia during labor: bupivacaine 1 mg/mL, bupivacaine 0.8 mg/mL with fentanyl 1 mcg/mL, or bupivacaine 0.625 mg/mL with fentanyl 2 mcg/mL. At 6 weeks postpartum, the breastfeeding rate was 94% or greater in all groups, with no difference among them. All mothers delivered full-term infants and were highly motivated to breastfeed and almost all had vaginal deliveries.[21]

A prospective cohort study in 1204 Israeli women on the effect of labor epidural analgesia during labor, the following protocol was used: bupivacaine 0.1% 15 mL and fentanyl 100 mcg in 5-mL increments, followed by an epidural infusion of bupivacaine 0.1% 10 mL and fentanyl 2 mcg/mL, with a patient-controlled epidural analgesia modality with 5 mL bolus with a lock-out time of 15 minutes. A 6 weeks postpartum, the breastfeeding and exclusive breastfeeding rates were lower (74% and 52%, respectively) in mothers who received the epidural analgesia than in those who did not (83% and 68%, respectively). However, the difference was mostly accounted for by parity, with the intervention having little effect on multiparous women.[22]

A retrospective study of women in a Turkish hospital who underwent elective cesarean section deliveries compared women who received bupivacaine spinal anesthesia (n = 170) to women who received general anesthesia (n = 78) with propofol for induction, sevoflurane for maintenance and fentanyl after delivery. No differences in breastfeeding rates were seen between the groups at 1 hour and 24 hours postpartum. However, at 6 months postpartum, 67% of women in the general anesthesia group were still breastfeeding compared to 81% in the spinal anesthesia group, which was a statistically significant difference.[23]

Possible alternatives to Bupivacaine

Lidocaine, Ropivacaine.

List of References

Lactation sources: Drugs and Lactation Database (LactMed) [Internet]. Bethesda (MD): National Library of Medicine (US); 2006-. Available from: https://www.ncbi.nlm.nih.gov/books/NBK501922/1. Reynolds F. Labour analgesia and the baby: good news is no news. Int J Obstet Anesth. 2011;20:38-50. PMID: 21146977
2. Loubert C, Hinova A, Fernando R. Update on modern neuraxial analgesia in labour: a review of the literature of the last 5 years. Anaesthesia. 2011;66:191-212. PMID: 21320088
3. Shrestha B, Devgan A, Sharma M. Effects of maternal epidural analgesia on the neonate – a prospective cohort study. Ital J Pediatr. 2014;40:99. PMID: 25492043
4. Zuppa A, Alighieri G, Riccardi R et al. Epidural analgesia, neonatal care and breastfeeding. Ital J Pediatr. 2014;40:82. PMID: 25432659
5. French CA, Cong X, Chung KS. Labor epidural analgesia and breastfeeding: A systematic review. J Hum Lact. 2016;32:507-20. PMID: 27121239
6. Naulty JS, Ostheimer G et al. Bupivacaine in breast milk following epidural anesthesia for vaginal delivery. Reg Anesth. 1983;8:44-5. Abstract.
7. Baker PA, Schroeder D. Interpleural bupivacaine for postoperative pain during lactation. Anesth Analg. 1989;69:400-2. PMID: 2774239
8. Ortega D, Viviand X et al. Excretion of lidocaine and bupivacaine in breast milk following epidural anesthesia for cesarean delivery. Acta Anaesthesiol Scand. 1999;43:394-7. PMID: 10225071
9. Bolat E, Bestas A, Bayar MK et al. Evaluation of levobupivacaine passage to breast milk following epidural anesthesia for cesarean delivery. Int J Obstet Anesth. 2014;23:217-21. PMID: 24953218
10. Hirose M, Hara Y et al. The effect of postoperative analgesia with continuous epidural bupivacaine after cesarean section on the amount of breast feeding and infant weight gain. Anesth Analg. 1996;82:1166-9. PMID: 8638785
11. Hirose M, Hosokawa T, Tanaka Y. Extradural buprenorphine suppresses breast feeding after cesarean section. Br J Anaesth. 1997;79:120-1. PMID: 9301399
12. Chang ZM, Heaman MI. Epidural analgesia during labor and delivery: effects on the initiation and continuation of effective breastfeeding. J Hum Lact. 2005;21:305-14. PMID: 16113019
13. Goma HM, Said RN, El-Ela AM. Study of the newborn feeding behaviors and fentanyl concentration in colostrum after an analgesic dose of epidural and intravenous fentanyl in cesarean section. Saudi Med J. 2008;29:678-82. PMID: 18454213
14. Sener EB, Guldogus N, Karakaya D et al. Comparison of neonatal effects of epidural and general anesthesia for cesarean section. Gynecol Obstet Investig. 2003;55:41-55. PMID: 12624551
15. Wilson MJ, Macarthur C, Cooper GM et al. Epidural analgesia and breastfeeding: a randomised controlled trial of epidural techniques with and without fentanyl and a non-epidural comparison group. Anaesthesia. 2009. PMID: 19912160
16. Bell AF, White-Traut R, Medoff-Cooper B. Neonatal neurobehavioral organization after exposure to maternal epidural analgesia in labor. J Obstet Gynecol Neonatal Nurs. 2010;39:178-90. PMID: 20409118
17. Wieczorek PM, Guest S, Balki M et al. Breastfeeding success rate after vaginal delivery can be high despite the use of epidural fentanyl: an observational cohort study. Int J Obstet Anesth. 2010;19:273-7. PMID: 20627690
18. Lind JN, Perrine CG, Li R. Relationship between use of labor pain medications and delayed onset of lactation. J Hum Lact. 2014;30:167-73. PMID: 24451212
19. Kutlucan L, Seker IS, Demiraran Y et al. Effects of different anesthesia protocols on lactation in the postpartum period. J Turkish German Gynecol Assoc Artemis. 2014;15:233-8. PMID: 25584032
20. Herrera-Gomez A, Garcia-Martinez O, Ramos-Torrecillas J et al. Retrospective study of the association between epidural analgesia during labour and complications for the newborn. Midwifery. 2015;31:613-6. PMID: 25819707
21. Lee AI, McCarthy RJ, Toledo P et al. Epidural labor analgesia-fentanyl dose and breastfeeding success: A randomized clinical trial. Anesthesiology. 2017;127:614-24. PMID: 28926440
22. Orbach-Zinger S, Landau R, Davis A et al. The effect of labor epidural analgesia on breastfeeding outcomes: A prospective observational cohort study in a mixed-parity cohort. Anesth Analg. 2018. PMID: 29847386
23. Karasu D, Yilmaz C, Ozgunay SE et al. A comparison of the effects of general anaesthesia and spinal anaesthesia on breastfeeding. C R Acad Bulg Sci . 2018;71:993-1000. DOI: doi:10.7546/CRABS.2018.07.17

Disclaimer: This material is provided for educational purposes only and is not intended for medical advice, diagnosis, or treatment. Consult your healthcare provider with any questions.

Read This Next

Articaine

Articaine and pregnancy or breastfeeding: Is it safe?

Read More

As seen in

Join our mailing list

Sign up for access to exclusive promotions, latest news and opportunites to test new pre-release products